About Schneider Pressure Transmitter IDP10S
Specifications
Main
| Range of Product |
Pressure |
| Product or Component Type |
Pressure transmitter |
| Type of Measurement |
Differential |
Complementary
| turndown |
400:1 |
| Response Time |
125 ms |
| mounting type |
Direct connect Low profile Biplanar |
| Measurement accuracy |
+/- 0.05 % of reading |
| Maximum pressure |
3000 psi 207 bar |
| drift |
+/- 0.03 % of measuring range per year, for 10 years |
| communication protocol |
FOUNDATION fieldbus HART |
Environment
| IP Degree of Protection |
IP67 |
| NEMA Degree of Protection |
NEMA 4X |
| Product certifications |
FM CSA ATEX IEC-Ex EAC INMETRO TV Rheinland (SIL3) NEPSI |
| Standards |
NACE MR01-03 |
Packing Units
| Unit Type of Package 1 |
PCE |
| Nbr. of units in pkg. |
1 |
Contractual warranty
| Warranty (in months) |
60 |
High Performance and ReliabilityThe IDP10S offers outstanding accuracy (0.075% of span) and rapid response time (<100 ms), supporting efficient control in demanding industrial applications. Its robust aluminum and stainless steel construction ensures long-term stability and consistent measurement, even in corrosive or hazardous environments.
Versatile Mounting and ApplicationDesigned for flexible installation, the transmitter supports 2-pipe or wall mounting. It is suitable for various sectors, from industrial processes and water treatment to environments requiring rigorous safety standards. Its compact design and multiple connection options enhance integration into existing systems.
User-Friendly Adjustments and SafetyAn external push-button enables easy zero/span calibration, and an optional LCD digital display provides real-time data. Certified explosion-proof (ATEX, FM, CSA), the device offers peace of mind and compliance for hazardous area applications, supported by IP67/NEMA 4X ingress protection.
FAQ's of Schneider Pressure Transmitter IDP10S:
Q: How do I perform zero or span adjustment on the IDP10S pressure transmitter?
A: Zero and span adjustments can be performed externally using the push-buttons located on the housing, ensuring convenient on-site calibration without the need to open the case or use additional equipment.
Q: What are the main benefits of using the IDP10S in harsh or hazardous environments?
A: The IDP10S offers high ingress protection (IP67/NEMA 4X), explosion-proof certifications (ATEX, FM, CSA), and robust materials such as 316L stainless steel and epoxy-coated aluminum, ensuring safe and reliable operation in demanding or hazardous settings.
Q: Where can the Schneider IDP10S pressure transmitter be installed?
A: This transmitter is field-mountable and can be installed using two-pipe or wall mounting. Its compact design and flexible connection options make it suitable for industrial sites, water treatment plants, or any location requiring precise pressure measurement.
Q: What output signal and power supply does the IDP10S require?
A: The IDP10S provides a standard 4-20mA analog output in a 2-wire configuration. It operates with a loop-powered supply in the range of 10.5-42V DC (recommended voltage: 12-36V DC).
Q: When should I use the optional LCD display feature?
A: The optional LCD digital display is beneficial when on-site pressure readings are needed for monitoring or troubleshooting, allowing users to view real-time data directly at the installation point.
Q: What process connections and electrical connections are available on this model?
A: The IDP10S features a 1/2"-14 NPT female process connection and allows for electrical connection via M20 x 1.5 or 1/2" NPT, facilitating compatibility with various industrial piping and wiring standards.
Q: How does the IDP10S ensure long-term measurement stability and safety?
A: Utilizing a capacitive pressure transducer design, the IDP10S offers high accuracy, overpressure protection, and stability. Compliance with IEC/EN standards and SIL2 certification further enhance reliability and safety for critical processes.