Main function
Motor Protection Circuit Breaker (MPCB)
Product series / family name
Power distribution > Low-voltage protection > Circuit breakers > Motor protection breakers
Sub-range name
MMP-T series
Functions
Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) / Manual motor starter protector
Design
frame 32
WS-V model
Trip current rating
0.25 AT
Frame current rating
32 AF
Rated operating voltage (Ue)
200-690 V
Rated impulse voltage (Uimp)
6 kV
Rated insulation voltage (Ui)
690 V
Connection type
Screw-clamp connection
Ultimate short circuit current breaking capacity (Icu)
100kA (200Vac; IEC60947)
100kA (240Vac; IEC60947)
100kA (400Vac; IEC60947)
100kA (415Vac; IEC60947)
100kA (440Vac; IEC60947)
100kA (460Vac; IEC60947)
100kA (500Vac; IEC60947)
100kA (600Vac; IEC60947)
100kA (690Vac; IEC60947)
Service short circuit current breaking capacity (Ics)
100kA (200Vac)
100kA (240Vac)
100kA (400Vac)
100kA (415Vac)
100kA (440Vac)
100kA (460Vac)
100kA (500Vac)
100kA (600Vac)
100kA (690Vac)
Service short circuit current breaking capacity as a percentage of Icu (Ics%)
(400Vac) 100 %
Trip unit type
Thermal-Magnetic (adjustable)
Protection functions
Thermal protection (Overload)
Magnetic protection (Short-circuit)
Protection settings
Thermal protection (Overload) -- adjustable tripping threshold 0.16A...0.25A
Mounting mode
Surface mounting (or DIN rail with optional adapter)
Electrical durability (with load)
100000 operations
Mechanical durability (at no load)
100000 operations
Utilisation category
AC-3
Order code / Manufacturer SKU
MMP-T32LF 0.25A
Manufacturer product status
Commercialized
Equivalent to
MMPT32LF025A
Compliant with standard(s)
IEC 60947-2
IEC 60947-4-1
EN 60947-2
EN 60947-4-1
GB14048.2
JIS C8201-2-1 Ann.1
JIS 8201-4-1
Benefits
Protects failure of the industrial motor by means of a single device One Motor Circuit Breaker can detect overload operation and phase-loss operation of a motor and also makes it possible to cut off short-circuit current.
This compact body Motor Circuit Breaker achieves a rated short-circuit breaking capacity of 100kA (200/240V).
Improves safety during product maintenance
The Motor Circuit Breaker is provided with a DIN and VDE standards-compliant charging part protection cover as standard.
This cover helps to improve safety during maintenance work.
Reduces the size of the control board and distribution board The internal structure of the Motor Circuit Breaker has been optimized to reduce depth.
When a connection conductor unit (UT-MT) is used it will further reduce the size of the control board and distribution board.
it can be assembled with an auxiliary contact/alarm contact unit as well as a short-circuit indicator unit (displays in red when short-circuit occurs) in a 45mm-width body.